Conservative closure of post-periodontal black triangles using the bioclear method

Professional headshot of smiling man in navy blazer and blue dress shirt against gray background Headshot

The Bioclear Method is a conservative, additive composite technique that closes black triangles following periodontal treatment by using anatomic mylar matrices to inject flowable composite into embrasure spaces, preserving tooth structure and maintaining accessibility for oral hygiene.

  • The Bioclear Method uses anatomic mylar matrices selected based on embrasure dimensions and positioned at 10° to 45° angles to guide composite placement and shape emergence profiles.
  • Proper surface preparation with biofilm removal, meticulous matrix adaptation, and controlled injection pressure minimize voids and ensure smooth, floss-friendly interproximal contours.
  • A total etch approach with flowable composite and strategic polishing using the Bioclear Rockstar technique produces natural results with uniform luster and no rough margins.
  • This technique allows patients to improve aesthetics and smile confidence without sacrificing healthy tooth structure or compromising their ability to maintain periodontal health.

Black triangles following periodontal treatment can present a restorative challenge, particularly when patients want to improve their smile without sacrificing healthy tooth structure. In this case, an additive composite injection-molding approach using the Bioclear Method was selected to close mandibular anterior embrasure spaces while establishing contours that would remain accessible for oral hygiene. 

Patient presentation and treatment planning

Headshot of Dr. Taras Konanec, co-owner of Drummond Dental Group in Montreal.Dr. Taras Konanec.

A 45-year-old woman presented in August 2026 seeking an aesthetic solution for black triangles affecting her mandibular anterior teeth. The spaces had become apparent following periodontal surgery approximately one year earlier. 

She had traveled from California specifically to consult a Bioclear provider and did not want conventional veneers or aggressive tooth preparation.

Clinical examination revealed multiple black triangles of varying dimensions across the lower anterior segment (Figure 1). 

Figure 1: A pretreatment mandibular anterior view showing multiple open gingival embrasures.Figure 1: A pretreatment mandibular anterior view showing multiple open gingival embrasures.Images courtesy of Dr. Taras Konanec/Kuraray Co. Ltd.

Although radiographs showed periodontal bone loss (Figure 2), her soft tissues were healthy, and she was maintaining periodontal health with visits to her periodontist every three months. No additional periodontal treatment was required before the restorative procedure.

Figure 2: pretreatment radiograph demonstrating reduced periodontal bone support in the lower anterior region.Figure 2: A pretreatment radiograph demonstrating reduced periodontal bone support in the lower anterior region.Because the embrasures differed in size, each was measured with the Bioclear Black Triangle Gauge to guide matrix selection. The treatment goals were to improve the tooth proportions, close the open gingival embrasures, and create smooth, natural emergence profiles without compromising the patient’s ability to maintain good oral hygiene.

Before treatment, unbonded composite was applied and quickly sculpted into a mock-up. This allowed the patient to visualize the proposed result within her smile while providing an opportunity to evaluate shade selection. 

Isolation and surface preparation

A rubber dam was placed, with isolation extending approximately from premolar to premolar (Figure 3). In addition to moisture control, the dam helped stabilize the matrices against the teeth during injection molding.

Figure 3: rubber dam isolation of the mandibular anterior teeth before matrix placement.Figure 3: Rubber dam isolation of the mandibular anterior teeth before matrix placement.

After calculus removal as needed, tooth surfaces were thoroughly cleaned to eliminate biofilm. Disclosing solution and a Bioclear Blaster with aluminum trihydroxide powder were used for this step. 

Meticulous surface preparation was particularly important because residual biofilm could compromise bonding and contribute to marginal discoloration over time. 

Matrix selection and placement

Bioclear anatomic mylar matrices were selected according to the dimensions of each black triangle and tried in before rubber dam placement. Recording the intended sequence was important because the embrasures required different matrices. 

The matrices were carefully advanced into the gingival sulcus to shape the cervical emergence profile (Figures 4 and 5).Figure 4: anatomic Mylar matrices positioned to define adjacent interproximal spaces.Figure 4: Anatomic Mylar matrices were positioned to define adjacent interproximal spaces.

Their angulation relative to the tooth varied with embrasure size, approximately 10° to 45° in this case. Correct selection and adaptation were essential to avoid excessive bulk and produce a smooth, floss-friendly interproximal surface. The aim was to retain the surface finish imparted by the Mylar wherever possible.

Figure 5: close-up of matrix adaptation and the planned emergence-profile contours.Figure 5: A close-up of the matrix adaptation and the planned emergence-profile contours.

Etching, bonding, and injection molding

A total etch approach was used: The enamel was etched for 15 seconds, then rinsed for 15 seconds. Clearfil Universal Bond Quick 2 (Kuraray Noritake Dental) was applied for approximately 10 seconds according to the clinician's reported protocol. For enamel-only bonding, the clinician proceeded to composite placement without separately light-curing the adhesive. 

Heated Clearfil Majesty ES Flow (Kuraray Noritake Dental) was selected as the restorative material, using shade B1 for the incisors and A1 for the canines. Due to its strength and polishability, the clinician used flowable composite alone to build the required contours.

Restoration began at the mandibular left canine and proceeded toward the right. At least two matrices were used together: one defined the embrasure receiving the composite, while the adjacent shield matrix preserved space for the next restoration. This method helped distribute the black triangle closure between neighboring teeth rather than adding all the bulk to one surface. 

Composite was injected against the matrix backstop to create controlled pressure and direct material into the matrix-defined space, a technique intended to minimize voids. Each restoration was light-cured using a Valo (Ultradent) unit for 20 seconds from the buccal aspect and 20 seconds from the lingual aspect.

Finishing and polishing

Excess material was reduced as needed, with a coarse diamond reserved for substantial overfill. A coarse 3M disc was then used to blend the composite with the facial tooth surface. Because the interproximal contours had already been formed by the matrices, those areas required minimal finishing. 

Polishing followed the Bioclear Rockstar approach. Bioclear Magic Mix polishing paste was applied with a prophylaxis cup in repeated three-second intervals to achieve an even matte finish. A diamond-impregnated Rockstar polisher was then used with light pressure and a gentle water spray until a uniform luster developed. 

Interproximal and subgingival margins were checked with floss, including floss susceptible to shredding, to identify any rough edges or overhangs. 

Outcome and clinical considerations

The completed restorations closed the visible mandibular black triangles and provided more continuous anterior contours (Figures 6 and 7). The patient reported that the result exceeded her expectations and that she felt more confident smiling in public and in photographs. Figure 6: post-treatment close-up showing closure of the mandibular black triangles.Figure 6: A post-treatment close-up showing closure of the mandibular black triangles.

Because the patient was traveling for work and returning to California, no postoperative follow-up findings were available at the time of writing. She was advised to tell her hygienist to avoid coarse prophylaxis pastes that might diminish the composite's polish; continued periodontal maintenance remains important. Figure 7: post-treatment retracted frontal view of the completed mandibular restorations.Figure 7: A post-treatment retracted frontal view of the completed mandibular restorations.

This case illustrates the importance of preparation and matrix setup in additive black triangle closure. Accurate measurement, individual matrix try-in, controlled injection pressure, and preservation of smooth emergence profiles all contributed to the immediate aesthetic result. Clinicians considering this technique should allow sufficient appointment time and avoid omitting steps that affect adaptation, contour, or surface finish.

Dr. Taras Konanec graduated in 1997 from McGill University and is the co-owner of Drummond Dental Group in Montreal, where he practices part time. He is a fellow of the Academy of General Dentistry and  is presently an assistant professor and the director of operative dentistry at the McGill University Faculty of Dental Medicine and Oral Health Sciences. Konanec is fully certified at all three levels of the Bioclear Method.  He has taught the Bioclear Method at McGill University for the last nine years and to hundreds of dentists.

The comments and observations expressed herein do not necessarily reflect the opinions of DrBicuspid.com, nor should they be construed as an endorsement or admonishment of any particular idea, vendor, or organization.

Page 1 of 442